SONARtrac
®
PROCESS MONITORING
SYSTEM
QUICK START GUIDE
CiDRA Corporation
Tel: 203 265 0035
50 Barnes Park North
Fax: 203 294 4211
Wallingford, CT 06492
www.cidra.com
CiDRA Corporation
Tel: 203 265 0035
50 Barnes Park North
Fax: 203 294 4211
Wallingford, CT 06492
www.cidra.com
CiDRA Corporation
Tel: 203 265 0035
50 Barnes Park North
Fax: 203 294 4211
Wallingford, CT 06492
www.cidra.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 29 30

Podsumowanie treści

Strona 1 - QUICK START GUIDE

SONARtrac® PROCESS MONITORING SYSTEM QUICK START GUIDE CiDRA Corporation Tel: 203 265 003550 Barnes

Strona 2

Menu Mode Key Operational Mode Navigation Editing Dialog Box Up Enter Menu Mode Cycle Menu Item Change current value at cursor position Exit Dialog

Strona 3 - List of Tables

• Press the ‘ENTER’ key to start the sensor test. Each of the sensors will be tested. If any sensor does not PASS, repeat the test. Individual se

Strona 4

3.2.1.2.2 Check / Set Gain Check / Set Gain allows the user to check the current gain setting in the pre-amplifier and to manually set it to one of

Strona 5 - 1 INTRODUCTION

• Press the ‘ENTER’ key to access the options available under that menu. • ‘Autoset Gain’ will appear on Line 3 of the display. • Press the ↓ key

Strona 6

3.2.2 Process Off-Line Some times the SONARtrac system is installed with the process off-line. In this case, it is not possible to verify the prope

Strona 7 - 2 TRANSMITTER LAYOUT

3.3 Operating Menu Setup 3.3.1 VF-100 System Initial Setup In order to conduct measurements, the ‘Basic Config’ setup must be completed. If power

Strona 8

• Following the entering of ‘Pipe Size’ press the ‘BACK’ key and ‘→Pipe Size’ will be displayed on Line 2. At this point the user can either press

Strona 9 - 3.1 Initial Start-up

desired format. Press the ‘ENTER’ key to set the desired date format followed by the ‘BACK’ key. • At this point ‘Basic Config’ is displayed on Lin

Strona 10 - 3.2.1 Process On-Line

• The third choice on the ‘Pipe Size’ menu is ‘OD / Wall’ displayed on Line 3. Use the arrow keys (↑ and ↓ to scroll through the values and ← and →

Strona 11 - 20984-01 Rev 01

arrow keys to enter the new value. This will result in a fixed pressure being used for GVF calculations. If a Pressure Transducer will be used to i

Strona 13

• Pressing the ↓ key will next display ‘→Calibration’ on Line 2. Press the ‘ENTER’ key and ‘→C0’ will appear on Line 3 and a numerical value on Line

Strona 14 - 3.2.2 Process Off-Line

4 HART COMMUNICATIONS 4.1 Introduction The SONARtrac transmitter implementation of HART supports HART Universal Command Revisions 5 and 6 as well as

Strona 15 - 3.3 Operating Menu Setup

4.2.2 4-20mA Transmitter and DCS Connections Connect to the appropriate terminals on the transmitter connector board. Figure 4 Transmitter Co

Strona 16

4.2.4 HART Activity Indicator When the SONARtrac receives a valid HART message, an indicator will appear on the lower right of the SONARtrac display

Strona 17

4.2.5.3 Preambles/Response Preambles The number of Preambles or Response Preambles should not need to be changed unless the 4-20mA current loop is no

Strona 18

4.2.6.9 PV Trim Value subtracted from the HART ‘Primary Variable’ (i.e. VF). 4.3 HART Troubleshooting 4.3.1 HART Master Does Not Connect to SONARtra

Strona 19

4.4 HART Commands The following is a list of supported HART commands. Command Name HART 5 or 6 Supported by CiDRA Universal Commands 0 Read uniq

Strona 20

50 Read dynamic variable assignments (4.1) HART 5 & 6 NO 51 Write dynamic variable assignments (4.1) HART 5 & 6 NO 52 Set transmitter vari

Strona 21 - 4 HART COMMUNICATIONS

*** This Page is Blank ***Copyright © 2007 CiDRA Corporation Page 4-820984-01 Rev 01

Strona 23 - 235 gal/min

Table of Contents 1 INTRODUCTION...1-1

Strona 24

CiDRA Corporation 50 Barnes Park North Wallingford, CT 06492 CiDRA Corporation 50 Barnes Park North Wallingford, CT 06492 (In U.S.):

Strona 25

*** This Page is Blank *** Copyright © 2007 CiDRA Corporation Page ii20984-01 Rev 01

Strona 26 - 4.4 HART Commands

1 INTRODUCTION 1.1 Purpose The purpose of this document is to provide an overview of the CiDRA SONARtrac system startup and operation. It is not in

Strona 27

*** This Page is Blank ***Copyright © 2007 CiDRA Corporation Page 1-220984-01 Rev 01

Strona 28 - *** This Page is Blank ***

2 TRANSMITTER LAYOUT 2.1 Transmitter Illustration The following figure illustrates the SONARtrac transmitter. Navigation ke

Strona 29

*** This Page is Blank ***Copyright © 2007 CiDRA Corporation Page 2-220984-01 Rev 01

Strona 30 - CiDRA Corporation

3 TRANSMITTER STARTUP AND OPERATION 3.1 Initial Start-up At initial power up the Green LED will light and the transmitter will display startup progr